Our new X account is live! Follow @wizwand_team for updates
WorkDL logo mark

Learning Hierarchical Attention for Weakly-supervised Chest X-Ray Abnormality Localization and Diagnosis

About

We consider the problem of abnormality localization for clinical applications. While deep learning has driven much recent progress in medical imaging, many clinical challenges are not fully addressed, limiting its broader usage. While recent methods report high diagnostic accuracies, physicians have concerns trusting these algorithm results for diagnostic decision-making purposes because of a general lack of algorithm decision reasoning and interpretability. One potential way to address this problem is to further train these models to localize abnormalities in addition to just classifying them. However, doing this accurately will require a large amount of disease localization annotations by clinical experts, a task that is prohibitively expensive to accomplish for most applications. In this work, we take a step towards addressing these issues by means of a new attention-driven weakly supervised algorithm comprising a hierarchical attention mining framework that unifies activation- and gradient-based visual attention in a holistic manner. Our key algorithmic innovations include the design of explicit ordinal attention constraints, enabling principled model training in a weakly-supervised fashion, while also facilitating the generation of visual-attention-driven model explanations by means of localization cues. On two large-scale chest X-ray datasets (NIH ChestX-ray14 and CheXpert), we demonstrate significant localization performance improvements over the current state of the art while also achieving competitive classification performance. Our code is available on https://github.com/oyxhust/HAM.

Xi Ouyang, Srikrishna Karanam, Ziyan Wu, Terrence Chen, Jiayu Huo, Xiang Sean Zhou, Qian Wang, Jie-Zhi Cheng• 2021

Related benchmarks

TaskDatasetResultRank
Abnormal classificationVinDr-Mammo (test)
AUC0.803
10
Asymmetric classificationVinDr-Mammo (test)
AUC80.5
10
Asymmetric classificationIn-house (test)
AUC0.887
10
Abnormal classificationIn-house (test)
AUC82.8
10
Abnormalities LocalizationINbreast
mTIoU25.7
10
Abnormalities LocalizationDDSM
Mean TIoU0.126
10
Abnormalities LocalizationVinDr-Mammo
mTIoU19.5
10
Abnormalities SegmentationINbreast
IoU22.8
10
Asymmetric classificationDDSM (test)
AUC93.1
10
Abnormal classificationDDSM (test)
AUC0.769
10
Showing 10 of 10 rows

Other info

Follow for update