Our new X account is live! Follow @wizwand_team for updates
WorkDL logo mark

PaPaGei: Open Foundation Models for Optical Physiological Signals

About

Photoplethysmography (PPG) is the leading non-invasive technique for monitoring biosignals and cardiovascular health, with widespread adoption in both clinical settings and consumer wearable devices. While machine learning models trained on PPG signals have shown promise, they tend to be task-specific and struggle with generalization. Current research is limited by the use of single-device datasets, insufficient exploration of out-of-domain generalization, and a lack of publicly available models, which hampers reproducibility. To address these limitations, we present PaPaGei, the first open foundation model for PPG signals. The model is pre-trained on over 57,000 hours of data, comprising 20 million unlabeled PPG segments from publicly available datasets. We introduce a novel representation learning approach that leverages domain knowledge of PPG signal morphology across individuals, enabling the capture of richer representations compared to traditional contrastive learning methods. We evaluate PaPaGei against state-of-the-art time-series foundation models and self-supervised learning benchmarks across 20 tasks from 10 diverse datasets, spanning cardiovascular health, sleep disorders, pregnancy monitoring, and wellbeing assessment. Our model demonstrates superior performance, improving classification and regression metrics by 6.3% and 2.9% respectively in at least 14 tasks. Notably, PaPaGei achieves these results while being more data- and parameter-efficient, outperforming models that are 70x larger. Beyond accuracy, we examine model robustness across different skin tones, establishing a benchmark for bias evaluation in future models. PaPaGei can serve as both a feature extractor and an encoder for multimodal models, opening up new opportunities for multimodal health monitoring.

Arvind Pillai, Dimitris Spathis, Fahim Kawsar, Mohammad Malekzadeh• 2024

Related benchmarks

TaskDatasetResultRank
ClassificationPPG Classification Benchmark Suite
Stress Accuracy96.01
14
Activity ClassificationActivity Classification Dataset
AUC85.76
7
Human IdentificationHuman Identification Dataset
AUC99.87
7
Diastolic BP RegressionDiastolic Blood Pressure Regression Dataset
MAE8.557
7
Heart Rate RegressionHeart Rate Regression Dataset
MAE1.086
7
SpO2 RegressionSpO2 Regression Dataset
MAE1.784
7
Affect ClassificationAffect Classification Dataset
AUC71.94
7
Average Heart Rate RegressionAverage Heart Rate
MAE4.174
7
Hypertension ClassificationHypertension Classification Dataset
AUC55.93
7
RegressionPPG Physiological Regression Suite (test)
Respiratory Rate Error2.41
7
Showing 10 of 22 rows

Other info

Follow for update