GreenRFM: Toward a resource-efficient radiology foundation model

About

The development of radiology foundation models (RFMs) is hindered by a reliance on brute-force scaling. Existing approaches often directly translate methods for natural images, which prioritize scale over precision and hence lead to brittle and expensive models in clinical practice. To address this, we present a resource-efficient pre-training framework, GreenRFM, that achieves state-of-the-art performance. Our framework ensures robust generalization across diverse patient populations and imaging protocols, reducing computational requirements by orders of magnitude while surpassing complex, parameter-heavy models. These capabilities stem from principled supervision design that aims to maximally utilize supervisory signals via More distilled, Ubiquitous, Semantic-enforcing, and Task-aligning (MUST) supervision, rather than simply piling up the quantity of training data. We offer two GreenRFM configurations: (i) a performant model that establishes a new state-of-the-art using a single 24GB GPU within 24 hours, and (ii) a lightweight model that matches existing benchmarks with 6GB VRAM in 4 hours. We conduct extensive experiments using over 200,000 images from four institutions and of two modalities. GreenRFMs achieve superior performances on chest and abdominal CT datasets, regardless of public or private benchmark, surpassing a range of baseline models. In addition, the results on internal musculoskeletal MRI images show that the same supervision principles transfer between different modalities. Our performance and efficiency challenge the ``scale is all you need'' dogma and democratize the equitable development of state-of-the-art RFMs for clinicians even on a laptop.

Yingtai Li, Shuai Ming, Mingyue Zhao, Haoran Lai, Rongsheng Wang, Rui Zhou, Rundong Wang, Yujia Li, Wei Wei, Shaohua Kevin Zhou• 2026

Related benchmarks

TaskDatasetResultRank
Abnormality diagnosisCT-RATE (internal val)
AUC84.8
13
Abnormality diagnosisRad-ChestCT (external val)
AUC78
11
Report-to-volume retrievalCT-RATE (test)
Recall@1016
9
Abnormality diagnosisMerlin (internal val)
F1 Score84.3
5
Report-to-volume retrievalMerlin n=5,082
Recall@522.5
3
Report-to-volume retrievalAH-Chest n=63,378
Recall@511
3
Report-to-volume retrievalAH-Abd
Recall@570
3
Diagnostic ClassificationAH-Chest
AUC74.5
2
Diagnostic ClassificationAH-Abd
AUC73.2
2
Showing 9 of 9 rows

Other info

Follow for update