Share your thoughts, 1 month free Claude Pro on usSee more
WorkDL logo mark

CAHAL: Clinically Applicable resolution enHAncement for Low-resolution MRI scans

About

Large-scale automated morphometric analysis of brain MRI is limited by the thick-slice, anisotropic acquisitions prevalent in routine clinical practice. Existing generative super-resolution (SR) methods produce visually compelling isotropic volumes but often introduce anatomical hallucinations, systematic volumetric overestimation, and structural distortions that compromise downstream quantitative analysis and diagnostic safety. To address this, we propose CAHAL (Clinically Applicable resolution enHAncement for Low-resolution MRI scans), a hallucination-robust, physics-informed resolution enhancement framework that operates directly in the patient's native acquisition space. CAHAL employs a deterministic bivariate Mixture of Experts (MoE) architecture routing each input through specialised residual 3D U-Net experts conditioned on both volumetric resolution and acquisition anisotropy, two independent descriptors of clinical MRI acquisition. Experts are optimised with a composite loss combining edge-penalised spatial reconstruction, Fourier-domain spectral coherence matching, and a segmentation-guided semantic consistency constraint. Training pairs are generated on-the-fly via physics-based degradation sampled from a large-scale real-world database, ensuring robust generalisation. Validated on T1-weighted and FLAIR sequences against generative baselines, CAHAL achieves state-of-the-art results, improving the best related methods in terms of accuracy and efficiency.

Sergio Morell-Ortega, \'Angela Gonz\'alez-Cebri\'an, Boris Mansencal, Marien Gadea, Roberto Vivo-Hernando, Gregorio Rubio, Fernando Aparici, Maria de la Iglesia-Vaya, Gwenaelle Catheline, Pierrick Coup\'e, Jos\'e V. Manj\'on• 2026

Related benchmarks

TaskDatasetResultRank
MRI Super-resolutionT1w MRI scans
PSNR (1.0-1.5 mm3)45.748
5
Resolution EnhancementMRI Scans T1w
LPIPS (1.0–1.5 mm3)0.026
5
Resolution EnhancementT1w MRI 1.0-1.5 mm³
Correlation Coefficient (CC)0.999
5
Resolution EnhancementT1w MRI 1.5-2.5 mm³
CC0.999
5
Resolution EnhancementT1w MRI 2.5-3.5 mm³
CC0.999
5
Resolution EnhancementT1w MRI 3.5-4.5 mm³
Correlation Coefficient (CC)0.998
5
Resolution EnhancementT1w MRI 4.5-5.5 mm³
Correlation Coefficient (CC)0.998
5
Resolution EnhancementT1w MRI 5.5-6.5 mm³
Correlation Coefficient (CC)0.997
5
Resolution EnhancementT1w MRI 6.5-10.5 mm³
CC99.7
5
Resolution EnhancementT1w MRI Overall
Correlation Coefficient (CC)0.998
5
Showing 10 of 21 rows

Other info