CEVAR: Centerline Embedding Extraction for Endovascular Aneurysm Repair

About

Long-term mortality rates after endovascular aneurysm repair (EVAR) remain elevated due to post-EVAR rupture caused by loss of seal in stent graft sealing zones. Structured CT review using centerline measurements improves detection, but current workflows require manual centerline editing and expert operators. We propose a transformer framework for automated, protocol-driven sealing zone assessment that combines 3D centerline tracking with embedding-based geometric prediction. Two state-of-the-art image-to-graph models are evaluated for aorto-iliac centerline extraction from follow-up CT and for measurement of stent position, vessel diameters, and seal lengths according to EVAR4C protocol. Across the full test set and a challenging no-contrast subset, the proposed fully automatic method outperforms the commercial semi-automatic workflow.

Roman Naeem, Timo Niiniskorpi, Charlotte Sandstr\"om, Naman Desai, Anders Jeppsson, Ida H\"aggstr\"om, Fredrik Kahl, H{\aa}kan Roos, Jennifer Alv\'en• 2026

Related benchmarks

TaskDatasetResultRank
Centerline ExtractionFull (test)
rAP76.12
9
Stent Centerline ExtractionStent Dataset non-contrast (test)
rAP68.69
9