Quantum CT via Dynamic Interval Encoding and Prior-Balanced QUBO Reconstruction
About
Quadratic unconstrained binary optimization (QUBO)-based quantum computed tomography (CT) casts reconstruction as a binary quadratic problem for quantum annealing and hybrid quantum--classical solvers. For grayscale CT, however, image encoding is constrained by the binary-variable budget: fixed global bit-plane encodings increase QUBO size and coupling complexity as gray-level precision improves, whereas low-bit encodings introduce quantization error. We propose a QUBO-based grayscale CT reconstruction framework that combines dynamic interval encoding with prior-balanced optimization. Each refinement round encodes active pixels only within local gray-level intervals around the current estimate, and a boundary-hit-guided update rule adaptively switches between search expansion and local refinement. To improve optimization stability, the method balances projection-domain data consistency and an edge-preserving quadratic prior before forming the final QUBO. Sparse-view and limited-angle fan-beam CT experiments show that the proposed method recovers structures and gray-level distributions more faithfully than the evaluated analytic, iterative, variational, and representation-based baselines. Expressivity analysis and ablation studies further indicate that the improvement mainly arises from effective gray-level representation through dynamic local encoding and more stable data-fidelity--prior coupling. Experiments on the D-Wave hybrid binary quadratic model (BQM) solver further demonstrate that the formulation is executable on a hardware-backed hybrid quantum--classical backend.
Related benchmarks
| Task | Dataset | Result | Rank | |
|---|---|---|---|---|
| Sparse-view reconstruction | Image 1 9 views (test) | PSNR45.13 | 9 | |
| Sparse-view reconstruction | Image 2 9 views (test) | PSNR39.14 | 9 | |
| Sparse-view reconstruction | Image 3 18 views (test) | PSNR37.93 | 9 | |
| Sparse-view reconstruction | Image 4 18 views (test) | PSNR40.36 | 9 | |
| Sparse-view reconstruction | Avg. across four cases Combined (test) | PSNR40.63 | 9 | |
| Limited-Angle CT Reconstruction | Phantom 60° angular span | PSNR29.76 | 4 | |
| Limited-Angle CT Reconstruction | Phantom 90° angular span | PSNR47.8 | 4 | |
| Limited-Angle CT Reconstruction | Phantom 120° angular span | PSNR51.93 | 4 | |
| Limited-Angle CT Reconstruction | Phantom 150° angular span | PSNR53.95 | 4 |