Share your thoughts, 1 month free Claude Pro on usSee more
WorkDL logo mark

Quantum CT via Dynamic Interval Encoding and Prior-Balanced QUBO Reconstruction

About

Quadratic unconstrained binary optimization (QUBO)-based quantum computed tomography (CT) casts reconstruction as a binary quadratic problem for quantum annealing and hybrid quantum--classical solvers. For grayscale CT, however, image encoding is constrained by the binary-variable budget: fixed global bit-plane encodings increase QUBO size and coupling complexity as gray-level precision improves, whereas low-bit encodings introduce quantization error. We propose a QUBO-based grayscale CT reconstruction framework that combines dynamic interval encoding with prior-balanced optimization. Each refinement round encodes active pixels only within local gray-level intervals around the current estimate, and a boundary-hit-guided update rule adaptively switches between search expansion and local refinement. To improve optimization stability, the method balances projection-domain data consistency and an edge-preserving quadratic prior before forming the final QUBO. Sparse-view and limited-angle fan-beam CT experiments show that the proposed method recovers structures and gray-level distributions more faithfully than the evaluated analytic, iterative, variational, and representation-based baselines. Expressivity analysis and ablation studies further indicate that the improvement mainly arises from effective gray-level representation through dynamic local encoding and more stable data-fidelity--prior coupling. Experiments on the D-Wave hybrid binary quadratic model (BQM) solver further demonstrate that the formulation is executable on a hardware-backed hybrid quantum--classical backend.

Ao Wang, Yikuang Yuluo, Yujie Liu, Shuangyang Zhong, Yuwen Zhang, Zihao Wang, Fenglin Liu, Andreas Maier, Haijun Yu, Yixing Huang• 2026

Related benchmarks

TaskDatasetResultRank
Sparse-view reconstructionImage 1 9 views (test)
PSNR45.13
9
Sparse-view reconstructionImage 2 9 views (test)
PSNR39.14
9
Sparse-view reconstructionImage 3 18 views (test)
PSNR37.93
9
Sparse-view reconstructionImage 4 18 views (test)
PSNR40.36
9
Sparse-view reconstructionAvg. across four cases Combined (test)
PSNR40.63
9
Limited-Angle CT ReconstructionPhantom 60° angular span
PSNR29.76
4
Limited-Angle CT ReconstructionPhantom 90° angular span
PSNR47.8
4
Limited-Angle CT ReconstructionPhantom 120° angular span
PSNR51.93
4
Limited-Angle CT ReconstructionPhantom 150° angular span
PSNR53.95
4
Showing 9 of 9 rows

Other info

Follow for update